CT-UART-001 Test Result
Go Back to the Pytest TEST All Index
Test summary
| Item |
Value |
| Description |
test_uart_timing |
| Category |
timing |
| Environment |
local |
| Result |
PASS |
| Execution time |
0.000 seconds |
| Execution date |
2026-08-19T10:04:32.972328+09:00 |
| Execution ID |
20260819_100432_972235 |
Test configs
| Test Item |
Value |
| Test ID |
CT-UART-001 |
| Category |
timing |
| Fixture ID |
FIXTURE-001 |
| Fixture mode |
mock |
| FIXTURE-001 |
Value |
| Interface |
UART |
| Equipment |
Saleae |
| Equipment mode |
mock |
| Interface mode |
mock |
Test Source
| Item |
Value |
| Commit |
2da8a43cba6d169d223ad51ee77bc4254f559c40 |
| Branch |
main |
Measurement
| Item |
Value |
| expected_baudrate |
921600 |
| measured_baudrate |
921596.667 |
| error |
3.6168981481902543e-06 |
| jitter |
0.00021701388888888888 |
Statistics
| Item |
Value |
| mean |
921596.6666666666 |
| median |
921602.5 |
| min |
921490.0 |
| max |
921690.0 |
| stddev |
67.55656066503748 |
Logs
- Path:
test_reports/results/pytest/test_cases/CT-UART-001
| Item |
Value |
| Test log |
20260819_100432_972235_test.log |
| Test Result |
20260819_100432_972235_result.json |
Local LLM Analysis
| Item |
Value |
| Classification |
Pass |
| Confidence |
0.98 |
| Analyzer |
ollama/deepseek-r1:7b |
| Status |
enabled |
LLM Test Prompt
analyze the test result and provide a detailed report with recommendations for improvement.
Test Result
| Item |
Value |
| Status |
PASS |
| Severity |
LOW |
| Warnings |
0 |
| Needs Escalation |
OFF |
Test Summary
| Item |
Value |
| Summary |
The test for CT-UART-001 executed successfully with minimal timing discrepancies. The measured_baudrate is 921596.667, which is extremely close to the expected 921600, resulting in a small error of 3.616e-06. The jitter observed is 0.000217, indicating very stable timing performance. The statistical analysis shows a mean and median within the expected range, with minimal variation across multiple runs. No critical or important issues were observed during the test. The equipment under test, Saleae UART, operates reliably in mock mode with no errors or warnings reported. |
| Failure Analysis |
No issues found during the test execution. All metrics are within acceptable limits. |
| Source Review |
The test source code and configurations appear to be correct, with no deviations from the expected setup. The test environment is properly configured and functioning as intended. |
| Warnings |
None |
| Recommendations |
1. Consider performing additional stress tests to further validate the equipment's stability under varying conditions. 2. Implement continuous monitoring of the UART interface to ensure real-time performance. 3. Review the test setup for any potential improvements in isolation testing. 4. It is recommended to conduct a comparative analysis with other UART devices for benchmarking purposes. |