CT-UART-001 Test Result
Go Back to the Pytest TEST All Index
Test summary
| Item |
Value |
| Description |
test_uart_timing |
| Category |
timing |
| Environment |
local |
| Result |
PASS |
| Execution time |
0.001 seconds |
| Execution date |
2026-08-19T10:29:18.438759+09:00 |
| Execution ID |
20260819_102918_438673 |
Test configs
| Test Item |
Value |
| Test ID |
CT-UART-001 |
| Category |
timing |
| Fixture ID |
FIXTURE-001 |
| Fixture mode |
mock |
| FIXTURE-001 |
Value |
| Interface |
UART |
| Equipment |
Saleae |
| Equipment mode |
mock |
| Interface mode |
mock |
Test Source
| Item |
Value |
| Commit |
7407acd01cc8747db64636b7cce7c06f6bd9de01 |
| Branch |
main |
Measurement
| Item |
Value |
| expected_baudrate |
921600 |
| measured_baudrate |
921596.667 |
| error |
3.6168981481902543e-06 |
| jitter |
0.00021701388888888888 |
Statistics
| Item |
Value |
| mean |
921596.6666666666 |
| median |
921602.5 |
| min |
921490.0 |
| max |
921690.0 |
| stddev |
67.55656066503748 |
Logs
- Path:
test_reports/results/pytest/test_cases/CT-UART-001
| Item |
Value |
| Test log |
20260819_102918_438673_test.log |
| Test Result |
20260819_102918_438673_result.json |
Local LLM Analysis
| Item |
Value |
| Classification |
Pass |
| Confidence |
0.95 |
| Analyzer |
ollama/deepseek-r1:7b |
| Status |
enabled |
LLM Test Prompt
analyze the test result and provide a detailed report with recommendations for improvement.
Test Result
| Item |
Value |
| Status |
PASS |
| Severity |
LOW |
| Warnings |
0 |
| Needs Escalation |
OFF |
Test Summary
| Item |
Value |
| Summary |
The test for UART timing (CT-UART-001) executed successfully without any errors. The measured baudrate is extremely close to the expected value, differing by a negligible amount of 3.6168981481902543e-06. The jitter observed is also minimal at 0.00021701388888888888 seconds, indicating low timing variability. The test configuration and setup appear to be functioning correctly, utilizing the Saleae equipment in mock mode with the UART interface. The overall performance meets the specified thresholds, and no warnings or critical issues were encountered. |
| Failure Analysis |
Test passed without any issues |
| Source Review |
Review complete. No significant issues identified. |
| Warnings |
None |
| Recommendations |
Continue using the current test setup as it is effective and reliable. No changes are needed to the test or equipment configuration. Consider optimizing the test environment further to ensure consistent performance across different scenarios if required. |