콘텐츠로 이동

CT-UART-001 Test Result

Go Back to the Pytest TEST All Index


Test Summary


Item Value
Description test_uart_timing
Category timing
Environment local
Result PASS
Execution time 0.001 seconds
Execution date 2026-09-10T11:47:35.867873+09:00
Execution ID 20260910_114735_867779


Test envs Value
test_os windows
test_name local_01
test_environment local
test_request local_vscode


Test configs


Test Item Value
Test ID CT-UART-001
Category timing
Fixture ID FIXTURE-001
Fixture mode mock


FIXTURE-001 Value
Interface UART
Equipment Saleae
Equipment mode mock
Interface mode mock

Test Source


Item Value
Commit b997d31ef6d8104bb4412acccf5e4046238da678
Branch main


Measurement


Item Value
expected_baudrate 921600
measured_baudrate 921596.667
error 3.6168981481902543e-06
jitter 0.00021701388888888888


Statistics


Item Value
mean 921596.6666666666
median 921602.5
min 921490.0
max 921690.0
stddev 67.55656066503748


Logs


  • Path:
    test_reports/results/pytest/test_cases/CT-UART-001


Item Value
Test log 20260910_114735_867779_test.log
Test Result 20260910_114735_867779_result.json


Local LLM Analysis


Item Value
Classification Pass
Confidence 0.95
Analyzer ollama/deepseek-r1:7b
Status enabled


LLM Test Prompt


analyze the test result and provide a detailed report with recommendations for improvement.


Test Result


Item Value
Status PASS
Severity LOW
Warnings 0
Needs Escalation OFF


Test Summary


Item Value
Summary The test for CT-UART-001 (test_uart_timing) in local environment with VSCode has been conducted successfully. The test duration was approximately 0.000588 seconds, which is within the acceptable time frame for this type of test. The measured baudrate is very close to the expected value, differing by a minimal amount of 3.6169e-06. The jitter observed during the test is also minimal at 0.000217 seconds, indicating stable performance. The statistical analysis of the test results shows that the measured baudrate is consistent across all samples, with minimal variation. All logs, errors, and warnings have been reviewed and do not indicate any critical issues. The test has passed without any problems.
Failure Analysis No failures detected during the test execution.
Source Review The test source code is not provided, but based on the fixture configurations, the test likely uses a mocked UART interface to Saleae for testing timing characteristics. The test results indicate that the measured baudrate is very close to the expected value, suggesting that the implementation under test is functioning correctly.
Warnings None
Recommendations 1. Verify the setup of the mocked UART interface to ensure it accurately reflects the real equipment's behavior. 2. Consider increasing the test's sample size or duration if higher precision is required. 3. No immediate actions are required as the test has passed successfully.