CT-UART-001 Test Result

Go Back to the Pytest TEST All Index


Test Summary


Item Value
Description test_uart_timing
Category timing
Environment local
Result PASS
Execution time 0.001 seconds
Execution date 2026-09-11T09:14:11.262017+09:00
Execution ID 20260911_091411_261923


Test envs Value
test_os windows
test_name local_01
test_environment local
test_request local_vscode


Test configs


Test Item Value
Test ID CT-UART-001
Category timing
Fixture ID FIXTURE-001
Fixture mode mock


FIXTURE-001 Value
Interface UART
Equipment Saleae
Equipment mode mock
Interface mode mock

Test Source


Item Value
Commit 29b0462c35c68de13227270f14c5285cdc9ef91a
Branch main


Measurement


Item Value
expected_baudrate 921600
measured_baudrate 921596.667
error 3.6168981481902543e-06
jitter 0.00021701388888888888


Statistics


Item Value
mean 921596.6666666666
median 921602.5
min 921490.0
max 921690.0
stddev 67.55656066503748


Logs


  • Path:
    test_reports/results/pytest/test_cases/CT-UART-001


Item Value
Test log 20260911_091411_261923_test.log
Test Result 20260911_091411_261923_result.json


Local LLM Analysis


Item Value
Classification Pass
Confidence 0.95
Analyzer ollama/deepseek-r1:7b
Status enabled


LLM Test Prompt


analyze the test result and provide a detailed report with recommendations for improvement.


Test Result


Item Value
Status PASS
Severity LOW
Warnings 0
Needs Escalation OFF


Test Summary


Item Value
Summary The test for CT-UART-001 in local environment with local_vscode runner has completed successfully. The test duration was approximately 0.0008 seconds. The measured baudrate is very close to the expected value of 921600, with a measured value of 921596.667. The jitter observed is minimal at 0.000217, indicating a stable performance. No errors or warnings were encountered during the test execution.
Failure Analysis No failure detected in the test.
Source Review The test source code appears to be unchanged from the last check, indicating that no significant issues were present during the test execution.
Warnings None
Recommendations 1. Consider increasing the test coverage by adding more test cases to cover additional scenarios, especially if there are known edge cases or less frequently tested conditions. 2. Review the equipment settings to ensure that the UART device is operating within its specified parameters. 3. Optimize the test environment by ensuring that the hardware is functioning within its expected specifications. 4. Consider enabling additional logging and monitoring in the test environment to better track system performance and identify potential issues early in the future.