CT-UART-001 Test Result
Go Back to the Pytest TEST All Index
Test Summary
| Item |
Value |
| Description |
test_uart_timing |
| Category |
timing |
| Environment |
local |
| Result |
PASS |
| Execution time |
0.001 seconds |
| Execution date |
2026-09-11T09:14:11.262017+09:00 |
| Execution ID |
20260911_091411_261923 |
| Test envs |
Value |
| test_os |
windows |
| test_name |
local_01 |
| test_environment |
local |
| test_request |
local_vscode |
Test configs
| Test Item |
Value |
| Test ID |
CT-UART-001 |
| Category |
timing |
| Fixture ID |
FIXTURE-001 |
| Fixture mode |
mock |
| FIXTURE-001 |
Value |
| Interface |
UART |
| Equipment |
Saleae |
| Equipment mode |
mock |
| Interface mode |
mock |
Test Source
| Item |
Value |
| Commit |
29b0462c35c68de13227270f14c5285cdc9ef91a |
| Branch |
main |
Measurement
| Item |
Value |
| expected_baudrate |
921600 |
| measured_baudrate |
921596.667 |
| error |
3.6168981481902543e-06 |
| jitter |
0.00021701388888888888 |
Statistics
| Item |
Value |
| mean |
921596.6666666666 |
| median |
921602.5 |
| min |
921490.0 |
| max |
921690.0 |
| stddev |
67.55656066503748 |
Logs
- Path:
test_reports/results/pytest/test_cases/CT-UART-001
| Item |
Value |
| Test log |
20260911_091411_261923_test.log |
| Test Result |
20260911_091411_261923_result.json |
Local LLM Analysis
| Item |
Value |
| Classification |
Pass |
| Confidence |
0.95 |
| Analyzer |
ollama/deepseek-r1:7b |
| Status |
enabled |
LLM Test Prompt
analyze the test result and provide a detailed report with recommendations for improvement.
Test Result
| Item |
Value |
| Status |
PASS |
| Severity |
LOW |
| Warnings |
0 |
| Needs Escalation |
OFF |
Test Summary
| Item |
Value |
| Summary |
The test for CT-UART-001 in local environment with local_vscode runner has completed successfully. The test duration was approximately 0.0008 seconds. The measured baudrate is very close to the expected value of 921600, with a measured value of 921596.667. The jitter observed is minimal at 0.000217, indicating a stable performance. No errors or warnings were encountered during the test execution. |
| Failure Analysis |
No failure detected in the test. |
| Source Review |
The test source code appears to be unchanged from the last check, indicating that no significant issues were present during the test execution. |
| Warnings |
None |
| Recommendations |
1. Consider increasing the test coverage by adding more test cases to cover additional scenarios, especially if there are known edge cases or less frequently tested conditions. 2. Review the equipment settings to ensure that the UART device is operating within its specified parameters. 3. Optimize the test environment by ensuring that the hardware is functioning within its expected specifications. 4. Consider enabling additional logging and monitoring in the test environment to better track system performance and identify potential issues early in the future. |